Phoenix Contact MCR-S10 Series Current Measuring Transducer, Current Input, Current Output, 20 → 30V dc Supply
Phoenix Contact Phoenix Contact MCR-S10 Series Current Measuring Transducer, Current Input, Current Output, 20 → 30V dc Supply Part: 2814728

Current measuring transducer converts high current input to standard 4-20mA signal.

Module Type: Current Transducer Input Signal Type: Current Output Signal Type: Current
Weidmuller ACT20X Series Signal Conditioner, Current Input, Current Output, 19.2 → 31.2V Supply, IECEx
Weidmüller Weidmuller ACT20X Series Signal Conditioner, Current Input, Current Output, 19.2 → 31.2V Supply, IECEx Part: 8965430000

Isolation amplifier converts 4-20mA input signal with ATEX-safe design for hazardous areas.

Module Type: Signal Isolator Input Signal Type: Current Output Signal Type: Current
Phoenix Contact MINI MCR Series Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 9.6 → 30V
Phoenix Contact Phoenix Contact MINI MCR Series Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 9.6 → 30V Part: 2902040

Multi-function signal conditioner accepts current and voltage inputs with selectable outputs.

Module Type: Signal Conditioner Input Signal Type: Current, Voltage Output Signal Type: Current, Voltage
Eaton MTL Series Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 18 → 32V dc Supply
Eaton Eaton MTL Series Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 18 → 32V dc Supply Part: MTL1211

Industrial signal conditioner module for current and voltage signal conversion and isolation.

Module Type: Switch/Proximity Detector Input Signal Type: Current, Voltage Output Signal Type: Current, Voltage
Phoenix Contact MINI MCR Series Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 24V dc Supply, ATEX
Phoenix Contact Phoenix Contact MINI MCR Series Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 24V dc Supply, ATEX Part: 2905026

ATEX signal duplicator for hazardous areas with current and voltage signal conversion.

Module Type: Signal Duplicator Input Signal Type: Current, Voltage Output Signal Type: Current, Voltage
Eaton MTL Series Signal Conditioner, Voltage Input, Relay Output, 40 V dc, 230V ac Supply
Eaton Eaton MTL Series Signal Conditioner, Voltage Input, Relay Output, 40 V dc, 230V ac Supply Part: MTL5514D

Voltage-sensing signal conditioner with relay output for industrial control applications.

Module Type: Switch/Proximity Detector Input Signal Type: Voltage Output Signal Type: Relay
Phoenix Contact MACX MCR Series Signal Conditioner, Current Input, Current Output, 9.6 → 30V dc Supply, ATEX
Phoenix Contact Phoenix Contact MACX MCR Series Signal Conditioner, Current Input, Current Output, 9.6 → 30V dc Supply, ATEX Part: 2905628

ATEX-certified repeater amplifier for 4-20mA signals in hazardous industrial areas.

Module Type: Repeater power supply Input Signal Type: Current Output Signal Type: Current
Phoenix Contact MACX MCR Series Signal Conditioner, Current Input, Current Output, <30.5V Supply, ATEX
Phoenix Contact Phoenix Contact MACX MCR Series Signal Conditioner, Current Input, Current Output, <30.5V Supply, ATEX Part: 2905278

Loop-powered isolation amplifier for 4-20mA signals with ATEX certification.

Module Type: Loop Powered Isolator Input Signal Type: Current Output Signal Type: Current
Phoenix Contact MACX MCR Series Signal Conditioner, Current Input, Current Output, <30.5V Supply, ATEX
Phoenix Contact Phoenix Contact MACX MCR Series Signal Conditioner, Current Input, Current Output, <30.5V Supply, ATEX Part: 2905280

Loop-powered isolation amplifier for 4-20mA signals with ATEX certification.

Module Type: Loop Powered Isolator Input Signal Type: Current Output Signal Type: Current
Phoenix Contact MACX MCR Series Signal Conditioner, Transistor Output, 19.2 → 30V dc Supply, ATEX, IECEx
Phoenix Contact Phoenix Contact MACX MCR Series Signal Conditioner, Transistor Output, 19.2 → 30V dc Supply, ATEX, IECEx Part: 2906155

Transistor output driver for solenoids and relays in ATEX-certified hazardous areas.

Module Type: Solenoid Driver Output Signal Type: Transistor Input Range: 19.2 → 30V dc
Phoenix Contact MINI MCR Series Signal Conditioner, Current, Voltage Input, Transistor Output, 9.6 → 30V dc
Phoenix Contact Phoenix Contact MINI MCR Series Signal Conditioner, Current, Voltage Input, Transistor Output, 9.6 → 30V dc Part: 2902028

Compact signal conditioner with transistor output for current and voltage monitoring.

Module Type: Signal Conditioner Input Signal Type: Current, Voltage Output Signal Type: Transistor
Eaton MTL5000/5500 Series Connecting Cable, ATEX
Eaton Eaton MTL5000/5500 Series Connecting Cable, ATEX Part: PCL45-USB

USB programming cable for configuring ATEX-rated MTL signal conditioning modules.

Module Type: Configurator Output Range: 4 → 20mA Hazardous Area Certification: ATEX
Jumo ecoTRANS Series Signal Conditioner, Conductivity, Temperature Input, Current, Voltage Output, 20 → 30V dc
Jumo Jumo ecoTRANS Series Signal Conditioner, Conductivity, Temperature Input, Current, Voltage Output, 20 → 30V dc Part: 202732/888-888-101/024

Transmitter converts conductivity and temperature sensor inputs to standard 4-20mA output.

Module Type: Conductivity Transmitter Input Signal Type: Conductivity, Temperature Output Signal Type: Current, Voltage
Phoenix Contact MINI MCR-2-CVCS-PT Series Signal Conditioner, ATEX
Phoenix Contact Phoenix Contact MINI MCR-2-CVCS-PT Series Signal Conditioner, ATEX Part: 2902065

ATEX-certified compact signal conditioner for current and voltage signals.

Hazardous Area Certification: ATEX Mounting Type: DIN Rail Operating Temperature Range: -40 → +70°C
Weidmuller ACT20X Series Signal Conditioner
Weidmüller Weidmuller ACT20X Series Signal Conditioner Part: 1160650000

Terminal block connector for ACT20X series DIN rail-mounted signal conditioning modules.

Module Type: Terminal Connection Mounting Type: DIN Rail Mount Series: ACT20X
Wago 857 Series Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 24V dc Supply, ATEX, IECEx
Wago Wago 857 Series Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 24V dc Supply, ATEX, IECEx Part: 857-400

ATEX-certified isolation amplifier for current and voltage signals in hazardous areas.

Module Type: Isolation Amplifier Input Signal Type: Current, Voltage Output Signal Type: Current, Voltage
Pepperl + Fuchs S1SD Series Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 16.8 → 31.2V dc
Pepperl + Fuchs Pepperl + Fuchs S1SD Series Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 16.8 → 31.2V dc Part: S1SD-1AI-1U.2

Flexible isolation amplifier supports multiple current and voltage signal configurations.

Module Type: Isolation Amplifier Input Signal Type: Current, Voltage Output Signal Type: Current, Voltage
Wago Signal Conditioner, Voltage Input, Current, Voltage Output, 24V dc Supply, ATEX, IECEx
Wago Wago Signal Conditioner, Voltage Input, Current, Voltage Output, 24V dc Supply, ATEX, IECEx Part: 857-819

ATEX-certified voltage signal converter for industrial control systems in explosive environments.

Module Type: Voltage Transducer Input Signal Type: Voltage Output Signal Type: Current, Voltage
Phoenix Contact MINI MCR Series Signal Conditioner, Current Input, Current Output, 18V Supply, ATEX
Phoenix Contact Phoenix Contact MINI MCR Series Signal Conditioner, Current Input, Current Output, 18V Supply, ATEX Part: 2864419

Industrial signal isolator converting 0-20mA current signals for explosive environments.

Module Type: Loop Powered Isolator Input Signal Type: Current Output Signal Type: Current
Murrelektronik Limited Signal Conditioner, RTD Input, Current, Voltage Output
Murrelektronik Limited Murrelektronik Limited Signal Conditioner, RTD Input, Current, Voltage Output Part: 44331

Industrial temperature converter that reads RTD sensors and outputs standardized current or voltage signals.

Module Type: Temperature Converter Input Signal Type: RTD Output Signal Type: Current, Voltage

Buy Signal Conditioners — Industrial Supply & Procurement

Browse 530 Signal Conditioners products available for procurement through AgaCanGroup. Top brands include Phoenix Contact, Weidmüller, RS PRO, PR Electronics, Siemens. All products are available via RFQ — submit your specification and ACG will respond within 24 hours with pricing, availability and delivery options. ACG serves procurement teams across Africa, the Middle East and South Asia.

<