ABB RCBO, 6A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, System Pro M Compact Range
ABB ABB RCBO, 6A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, System Pro M Compact Range Part: 2CSR255051R1064 DSE201 C6 AC30 - N Blue

ABB 6A combined circuit breaker and earth leakage protector for single-phase circuits.

Current Rating: 6A Number of Poles: 1P+N Trip Sensitivity: 30mA
Schneider Electric RCBO, 20A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Acti 9 Range
Schneider Electric Schneider Electric RCBO, 20A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Acti 9 Range Part: A9D19820

Schneider 20A combined circuit breaker with earth leakage protection for single-phase wiring.

Current Rating: 20A Number of Poles: 1P+N Trip Sensitivity: 30mA
Legrand RCD Switch, 20A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, DX Range
Legrand Legrand RCD Switch, 20A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C, DX Range Part: 4 107 86

Legrand 20A safety breaker combining overcurrent and earth leakage protection for homes.

Current Rating: 20A Number of Poles: 1P+N Trip Sensitivity: 30mA
Schneider Electric RCBO, 10A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Acti 9 Range
Schneider Electric Schneider Electric RCBO, 10A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Acti 9 Range Part: A9D31810

Schneider 10A protective breaker combining overload and earth leakage detection.

Current Rating: 10A Number of Poles: 1P+N Trip Sensitivity: 30mA
Schneider Electric RCBO, 20A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type C, Acti 9 Range
Schneider Electric Schneider Electric RCBO, 20A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type C, Acti 9 Range Part: A9D11220

Schneider 20A two-pole safety breaker for dual-phase circuits with earth fault detection.

Current Rating: 20A Number of Poles: 2 Trip Sensitivity: 30mA
Schneider Electric RCBO, 32A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type B, Acti 9 Range
Schneider Electric Schneider Electric RCBO, 32A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type B, Acti 9 Range Part: A9D56632

Schneider 32A protective breaker with earth leakage detection for higher-load circuits.

Current Rating: 32A Number of Poles: 1P+N Trip Sensitivity: 30mA
Lovato RCBO, 10A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C
Lovato Lovato RCBO, 10A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C Part: P1RB1NC10AC300

Lovato 10A protective breaker with 300mA earth leakage sensitivity for equipment protection.

Current Rating: 10A Number of Poles: 1P+N Trip Sensitivity: 300mA
Lovato RCBO, 16A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C
Lovato Lovato RCBO, 16A Current Rating, 1P+N Poles, 300mA Trip Sensitivity, Type C Part: P1RB1NC16AC300

Lovato 16A protective breaker for moderate circuits with 300mA earth fault detection.

Current Rating: 16A Number of Poles: 1P+N Trip Sensitivity: 300mA
Siemens RCBO, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type C, Sentron Range
Siemens Siemens RCBO, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type C, Sentron Range Part: 5SU1356-7KK16

Siemens 16A two-pole safety breaker for dual-phase circuits with earth protection.

Current Rating: 16A Number of Poles: 2 Trip Sensitivity: 30mA
Schneider Electric RCBO, 25A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type B, Acti 9 Range
Schneider Electric Schneider Electric RCBO, 25A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type B, Acti 9 Range Part: A9D56625

Schneider 25A protective breaker for distribution circuits with earth leakage safety.

Current Rating: 25A Number of Poles: 1P+N Trip Sensitivity: 30mA
Siemens RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity, Sentron Range
Siemens Siemens RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity, Sentron Range Part: 5SU1354-7KK40

Siemens 40A two-pole protective breaker for heavy-load dual-phase circuits.

Current Rating: 40A Number of Poles: 2 Trip Sensitivity: 30mA
Siemens RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity, Sentron Range
Siemens Siemens RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity, Sentron Range Part: 5SU1356-6KK40

Siemens 40A two-pole safety breaker for heavy industrial or commercial dual-phase loads.

Current Rating: 40A Number of Poles: 2 Trip Sensitivity: 30mA

Buy RCBO-Residual Current Circuit Breakers — Industrial Supply & Procurement

Browse 1,012 RCBO-Residual Current Circuit Breakers products available for procurement through AgaCanGroup. Top brands include ABB, Siemens, Schneider Electric, Lovato, Contactum. All products are available via RFQ — submit your specification and ACG will respond within 24 hours with pricing, availability and delivery options. ACG serves procurement teams across Africa, the Middle East and South Asia.

<
My RFQ Basket

Your RFQ basket is empty

Browse the catalogue and add items to your requirement list Browse catalogue
Compare

Add 2 or 3 products to compare

Compare now →