ACG
Loading
PART OF THE NOVA PLATFORM ECOSYSTEM · KAMPALA, UGANDA · MALATYA, TURKEY
Browse by Department
Services About Contact
Submit RFQ →
You searched for "N-RPSMA"
19 products found · 1 categories · Top brands: Eaton
Showing 1–19 of 19 products
Eaton RCCB, 80A, 1P+N Pole, 30mA, Type AC
Eaton Eaton RCCB, 80A, 1P+N Pole, 30mA, Type AC Part: 235402 PFIM-80/2/003-MW

Large single-phase RCD with high sensitivity earth fault detection for heavy-duty circuits.

Eaton RCCB, 63A, 1P+N Pole, 100mA, Type AC
Eaton Eaton RCCB, 63A, 1P+N Pole, 100mA, Type AC Part: 235399 PFIM-63/2/01-MW

Large single-phase RCD for industrial and commercial applications with high earth fault sensitivity.

Eaton RCCB, 40A, 1P+N Pole, 30mA, Type AC
Eaton Eaton RCCB, 40A, 1P+N Pole, 30mA, Type AC Part: 235394 PFIM-40/2/003-MW

Single-phase RCD with high sensitivity for personnel protection in damp environments.

110 → 130V ac Undervoltage Release Circuit Trip for use with N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4)
Eaton 110 → 130V ac Undervoltage Release Circuit Trip for use with N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4) Part: 259589 NZM2/3-XUHIV110-130AC

Undervoltage release trip module for Eaton circuit breakers, cuts power when voltage drops below safe levels.

380 → 440V ac Undervoltage Release Circuit Trip for use with N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4)
Eaton 380 → 440V ac Undervoltage Release Circuit Trip for use with N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4) Part: 259594 NZM2/3-XUHIV380-440AC

Undervoltage trip device for Eaton circuit breakers, cuts power if voltage drops below safe levels.

208 → 240V ac Undervoltage Release Circuit Trip for use with N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4)
Eaton 208 → 240V ac Undervoltage Release Circuit Trip for use with N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4) Part: 259591 NZM2/3-XUHIV208-240AC

Eaton undervoltage release trip module for circuit breakers, rated 208-240V AC.

208 → 250V ac/dc Shunt Trip Shunt trip for use with N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4) Series,
Eaton 208 → 250V ac/dc Shunt Trip Shunt trip for use with N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4) Series, Part: 259763 NZM2/3-XA208-250AC/DC

Electrical shunt trip module for remote circuit breaker activation on industrial control systems.

380 → 440V ac/dc Shunt Trip Shunt trip for use with N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4) Series,
Eaton 380 → 440V ac/dc Shunt Trip Shunt trip for use with N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4) Series, Part: 259766 NZM2/3-XA380-440AC/DC

Eaton shunt trip device for circuit breaker remote emergency shutdown control systems.

24V ac/dc Shunt Trip Shunt trip for use with N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4) Series, NZM3(-4) Series
Eaton 24V ac/dc Shunt Trip Shunt trip for use with N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4) Series, NZM3(-4) Series Part: 259754 NZM2/3-XA24AC/DC

24V shunt trip device for Eaton circuit breakers in industrial electrical systems.

Eaton RCCB, 40A, 3P+N Pole, 30mA, Type AC
Eaton Eaton RCCB, 40A, 3P+N Pole, 30mA, Type AC Part: 235410 PFIM-40/4/003-MW

Eaton 40A safety circuit breaker for three-phase power protection installations.

Eaton RCCB, 80A, 1P+N Pole, 100mA, Type AC
Eaton Eaton RCCB, 80A, 1P+N Pole, 100mA, Type AC Part: 235403 PFIM-80/2/01-MW

80A residual current circuit breaker for electrical shock protection in single-phase installations.

Eaton RCCB, 25A, 1P+N Pole, 100mA, Type AC
Eaton Eaton RCCB, 25A, 1P+N Pole, 100mA, Type AC Part: 235391 PFIM-25/2/01-MW

Safety circuit breaker that cuts power instantly if dangerous ground faults are detected.

Eaton RCCB, 40A, 1P+N Pole, 100mA, Type AC
Eaton Eaton RCCB, 40A, 1P+N Pole, 100mA, Type AC Part: 235395 PFIM-40/2/01-MW

Safety circuit breaker protecting against electric shock in single-phase installations.

Eaton RCCB, 25A, 1P+N Pole, 30mA, Type AC, 230V ac
Eaton Eaton RCCB, 25A, 1P+N Pole, 30mA, Type AC, 230V ac Part: 235390 PFIM-25/2/003-MW

Eaton safety switch protecting against electrical shocks in homes and offices.

24V ac Undervoltage Release Circuit Trip for use with N(S)1(-4), NZM1(-4)
Eaton 24V ac Undervoltage Release Circuit Trip for use with N(S)1(-4), NZM1(-4) Part: 259434 NZM1-XU24AC

24V AC undervoltage trip unit for Eaton circuit breakers and motor starters.

208 <arrow/> 240V ac Undervoltage Release Circuit Trip for use with N(S)1(-4), NZM1(-4)
Eaton 208 <arrow/> 240V ac Undervoltage Release Circuit Trip for use with N(S)1(-4), NZM1(-4) Part: 259442 NZM1-XU208-240AC

Undervoltage trip release for Eaton circuit breakers, cuts power when voltage drops dangerously.

24V ac/dc Shunt Trip Shunt trip for use with N(S)1(-4) Series, NZM1(-4) Series
Eaton 24V ac/dc Shunt Trip Shunt trip for use with N(S)1(-4) Series, NZM1(-4) Series Part: 259708 NZM1-XA24AC/DC

24V shunt trip control device for Eaton circuit breakers and motor protectors.

208 → 250V ac/dc Shunt Trip Shunt trip for use with N(S)1(-4) Series, NZM1(-4) Series
Eaton 208 → 250V ac/dc Shunt Trip Shunt trip for use with N(S)1(-4) Series, NZM1(-4) Series Part: 259726 NZM1-XA208-250AC/DC

Electrical shunt trip device for remote circuit breaker operation and control.

380 → 440V ac/dc Shunt Trip Shunt trip for use with N(S)1(-4) Series, NZM1(-4) Series
Eaton 380 → 440V ac/dc Shunt Trip Shunt trip for use with N(S)1(-4) Series, NZM1(-4) Series Part: 259728 NZM1-XA380-440AC/DC

Eaton 380-440V shunt trip for NZM1 series circuit breakers.

My RFQ Basket

Your RFQ basket is empty

Browse the catalogue and add items to your requirement list Browse catalogue